TER-INOX

TERi-INOX – isolated model

Heating elements with screw-in fittings are used for direct liquid heating. They are mainly used in water heaters, solar systems, buffer tanks, accumulators, and stainless steel tanks.
The product consists of one tubular heating element and a capillary protection installed in a head with a 5/4” or 6/4” thread. The heating element features a plastic housing, temperature control (5-70°C), and ECO-POINT function – optimal thermostat setting. It also includes an innovative non-self-resetting temperature limiter TSR 87°C and an operational mode indicator. The heating elements are made of acid-resistant steel of the Incoloy type. The heater is standardly equipped with a power supply cable with a plug, 1500mm in length. It meets the latest quality standards PN-EN 60335-1:2012, LVD 2014/35/EU.

Files to download

Download the product card in PDF format to learn more.

Technical Data
Application Stainless steel tanks (TER-INOX), Enamelled tanks (TERi-INOX)
Operating Pressure max. 10Bar
Sealing Degree of Cover IP44
Temperature Regulation 5-70°C
Indicator Light Red, built-in

Technical drawing

TER-INOX specification

Type Heating Power [W] Supply Voltage [V] Immersion Length L [mm] Dead Zone [mm] Threaded Connection Net Weight [kg]
TER-1500-54-INOX 1500 230~ 360 80 5/4″ 0.96
TER-2000-54-INOX 2000 230~ 360 80 5/4″ 0.98
TER-3000-54-INOX 3000 230~ 400 80 5/4″ 1.00
TER-1500-64-INOX 1500 230~ 360 80 6/4″ 0.98
TER-2000-64-INOX 2000 230~ 360 80 6/4″ 1.00
TER-3000-64-INOX 3000 230~ 400 80 6/4″ 1.02

TER-INOX isolated model specification

Type Heater power [W] Supply voltage [V] Immersion length L [mm] Dead zone [mm] Threaded connection Net weight [kg]
TERi-1500-54-INOX 1500 230~ 360 80 5/4″ 0.96
TERi-2000-54-INOX 2000 230~ 360 80 5/4″ 0.98
TERi-3000-54-INOX 3000 230~ 400 80 5/4″ 1.00
TERi-1500-64-INOX 1500 230~ 360 80 6/4″ 0.98
TERi-2000-64-INOX 2000 230~ 360 80 6/4″ 1.00
TERi-3000-64-INOX 3000 230~ 400 80 6/4″ 1.02

When ordering, please specify:

  • Power [W]
  • Voltage [V]
  • Length [mm]
  • Thread size
  • Quantity [pcs]

A technical drawing or a heater sample is welcome.