Language:

Phone: +48 89 741 73 75

Termik Sp. z o.o.Marcinkowo 106, 11-700 Mrągowo

Back
przeplywowe-zespoly-grzejne-1
przeplywowe-zespoly-grzejne-2
przeplywowe-zespoly-grzejne-3

Description

EX-Flow Heaters are used for direct heating of liquid and gas liquids. The design of the heaters is based on the general conditions (fluid type and properties, temperature, pressure, etc.). The assemblies are made of tubular or ceramic heaters in shields that are welded to the collar. The whole is placed in a protective tube. They are terminated with a control box with IP54 or IP65 protection.

Application

  • drinking water, circulating water, deionized water, demineralized water, etc.
  • hydraulic oil, lubricating oil, cooking oil, heating oil, bitumen, etc.
  • air, natural gas, exhaust gases, nitrogen, etc.

Specification

1. Tubular heaters

Diameter 8,5mm/10,0mm/12,0mm/16,0mm
Material 1.4404, 1.4571, 1.4828, 1.4876, 2.4858
Immersion length max. 2600mm
Shape "U"-shape
Electrical connection M4-M6


2. Replaceable heating elements

Diameter with cover 19,0mm - 63,5mm
Cartridge material technical ceramic
Cover material stainless steel
Cover Immersion length max. 2100mm
Shape straight
Electrical connection M4-M6


3. Thread

Thread material stainless steel
Dimensions G1 1/2'' - SW60; G2'' - SW70, G2 1/2'' - SW85


4. Flange

Type Standard (wg DIN/ANSI), wykonanie specjalne
Material boiler steel; stainless steel; 1.4301; 1.4404; 1.4541; 1.4571
Diameter to be agreed
Flange pressure to be agreed


5. Osłona rurowa

Type single/cascade
Material powierzchnia "surowa" lub malowana; steel węglowa; stainless steel; 1.4301; 1.4541; 1.4571
Others possibility to make casing with insulation


6. Control

Ex-flow heaters can be equipped with a built-in control system (low power) or a separate external control cabinet. The heating power can be divided into one or several heating sections.

A. Temperature controllers:

  • electronic ON / OFF control
  • thyristors
  • thermostats with a capillary

B. Sensors:

  • PT100
  • temperature limiter with a capillary
  • other thermocouples

Call +48 89 741 73 75 or fill in the form


*
*
*
*